Stainless steel Thermocouple cables
Stainless steel Thermocouple cables

Stainless steel Thermocouple cables

Price 100 INR/ Meter

Stainless steel Thermocouple cables Specification

  • Rated Temperature
  • -60C to +400C (standard), up to +800C for mineral insulated type
  • Insulation
  • Mineral or Fiberglass or PTFE Insulated
  • Conductor Type
  • Solid or Stranded
  • Core Number
  • 2 or 3 cores
  • Impedance
  • Low impedance for accurate signal
  • Tensile Strength
  • High, suitable for industrial environments
  • Core Material
  • Nickel alloys or as per thermocouple requirement
  • Weight
  • Varies as per length and construction
  • Diameter
  • 2mm up to 10mm (customized)
  • Armored Material
  • Stainless Steel, Optional GI armor
  • Features
  • Corrosion resistant, Flexible, High temperature stability, Durable against mechanical stress, Accurate signal transmission, Stainless steel sheath
  • Conductor Shape
  • Round
  • Install Type
  • Flexible, Suitable for conduit & open install
  • Locking Type
  • Screw or spring loaded connectors
  • Cable Type
  • Sheathed, Armored, or Mineral Insulated
  • Usage & Applications
  • Industrial thermal measurement, ovens, kilns, furnaces, scientific equipment
  • Operating Temperature
  • -60C to +800C (Depending on construction)
  • Number of Conductor
  • 2 (Single Pair) or as per order
  • Dielectiric Strength
  • 2000V AC/min
  • Product Type
  • Stainless steel Thermocouple cables
  • Length
  • Customizable (Standard lengths: 1m, 5m, 10m, up to 100m)
  • Voltage
  • 300V
  • Insulation Material
  • FG (Fiberglass), PTFE, or Mineral Insulated
  • Application
  • Industrial
  • Conductor Material
  • Nickel-Chromium alloys (for K type), Copper, or as per thermocouple type
  • Jacket Material
  • Stainless Steel (SS304/SS316), Teflon
  • Storage Temperature
  • -40C to +60C
  • Connector Color
  • Standardized as per IEC/ANSI thermocouple type
  • Shield Material
  • Stainless Steel Braided
  • Jacket Color
  • Metallic silver
  • Dimension (L*W*H)
  • Dependent on cable type and customization
  • Material
  • Stainless Steel sheath with specified core materials
  • Color
  • Metallic (Stainless Steel color)
  • Size
  • OD 2mm to 10mm or as specified
  • Available Types
  • J, K, T, E, N, S, R, B (Specify while ordering)
  • Moisture Resistance
  • Excellent, suitable for harsh environments
  • Compliance Standards
  • ASTM E230/E230M, IEC584, ANSI MC96.1
  • Lead Wire Type
  • Extension or Compensating, as per thermocouple type
  • Shield Type
  • Stainless Steel Braid or Double Sheath
  • Fire Resistance
  • Resistant to flame with mineral insulation
  • Minimum Bending Radius
  • 5 times cable outer diameter
  • EMI/RFI Protection
  • High, due to full metallic shielding
  • Crush Resistance
  • Excellent, due to armored construction
 

Stainless steel Thermocouple cables Trade Information

  • Minimum Order Quantity
  • 50 Meter
  • Supply Ability
  • 500 Per Week
  • Delivery Time
  • 3 Days
 

About Stainless steel Thermocouple cables



Encounter a transcendent deal with our Stainless Steel Thermocouple Cables -lending ephemeral excellence with durable prowess. Crafted for the virtuoso engineer, these cables feature a perfect blend of mechanical strength and corrosion resistance. High EMI/RFI protection from full metallic shielding ensures accurate signal transmission even in harsh environments. Flexible installation, moisture resistance, and fire-retardant mineral insulation secure dependable performance. Redeem reliability with standards-compliant design (ASTM E230/E230M, IEC584, ANSI MC96.1). Available in specified thermocouple types J, K, T, E, N, S, R, B, these cables deliver accurate readings and longevity-making them indispensable for any industrial application.

Enhanced Features, Application Method, and Plant Utility

Our stainless steel thermocouple cables boast extra features like high crush and fire resistance, exemplary EMI/RFI shielding, and flexibility for easier routing. Installations in plant environments are streamlined-these cables can be installed within conduits, trays, or open spaces. They are tailored for demanding plant applications, such as ovens, kilns, scientific setups, and critical furnace monitoring, ensuring durable and accurate temperature measurement. The rugged construction perfectly suits both new installations and retrofits in severe industrial conditions.


Export Destinations, Packaging, and Shipping Information

Our cables are offered to global markets with precise quotation and custom packaging. Main export destinations include Europe, Asia, Americas, and Africa. Shipped goods are carefully packed in robust, moisture-resistant cartons, coils, or customized crates as required. FOB port options include major Indian harbors with reliable transport services ensuring timely delivery. Export documentation and tracking ensure your consignments are managed with the highest standards, making international procurement seamless and dependable for every client.


FAQ's of Stainless steel Thermocouple cables:


Q: How do I select the correct thermocouple cable type for my application?

A: Choose the thermocouple cable type (J, K, T, E, N, S, R, or B) based on the temperature range and compatibility with your measuring instrument. Refer to application requirements or consult our technical team for tailored recommendations.

Q: What installation methods are recommended for these cables in industrial plants?

A: The cables can be installed in conduits, cable trays, or directly in open environments. Their stainless steel sheath and armored design make them flexible for tight bends while maintaining mechanical integrity, suited for both new installations and upgrades.

Q: When should mineral insulated cables be considered over other insulation types?

A: Mineral insulated cables are best for applications demanding higher temperature resistance, superior fire safety, and harsh environmental durability. Use them in ovens, furnaces, or areas where flame and moisture risk are paramount.

Q: Where can these stainless steel thermocouple cables be used?

A: They are ideal for industrial settings such as power plants, chemical processing, kilns, ovens, furnaces, laboratories, and scientific equipment-anywhere precise thermal measurement in challenging conditions is critical.

Q: What benefits do full metallic shielding and EMI/RFI protection offer?

A: Full metallic shielding provides high EMI/RFI protection, ensuring your temperature data remains accurate and unaffected by electrical noise in busy industrial environments, enhancing operational reliability.

Q: How is the product shipped, and what packaging is provided?

A: Shipped goods are protected with moisture-resistant packaging such as coils or crates. Transport services are coordinated through major Indian ports with careful attention to packaging details, ensuring safe arrival at your destination.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Thermocouple Cables Category

Pvc Thermocouple cables

Pvc Thermocouple cables

Price 100 INR / Meter

Minimum Order Quantity : 50

Core Material : Copper/Nickel Alloy

Jacket Material : PVC

Impedance : As required for thermocouple signal integrity

Tensile Strength : Greater than 15 N/mm2

Asbestos Thermocouple cables

Asbestos Thermocouple cables

Price 100 INR / Meter

Minimum Order Quantity : 50

Core Material : Thermocouple grade alloys

Jacket Material : Other, Asbestos braided jacket

Impedance : Low

Tensile Strength : High, suitable for robust industrial usage

Thermocouples And RTD Cable

Thermocouples And RTD Cable

Price 250 INR / Unit

Minimum Order Quantity : 1 Unit

Core Material : Copper / Nickel

Jacket Material : Other, PVC, Silicon, PTFE, Fiberglass

Impedance : Low

Tensile Strength : High

Silicon Thermocouple cables

Silicon Thermocouple cables

Price 100 INR / Meter

Minimum Order Quantity : 50

Core Material : NickelChromium/NickelSilicon or standard thermocouple alloy

Jacket Material : Other, Silicone Rubber

Impedance : Standard as per thermocouple type

Tensile Strength : >10N/mm2